Guide Specification
Planter Technology Fiberglass Planter Liners
1.0 GENERAL
1.1 WORK INCLUDED
- Provision of thermoplastic planter liners
1.2 RELATED WORK
- Section 03300 Cast-in-Place concrete
- Section 06100 Rough Carpentry
- Section 06200 Finish Carpentry
1.3 SUBMITTALS
- Product Data: Manufacturer's standard catalog cut sheets.
- Samples: As required for color selection or material thickness only.
- Shop Drawings: For custom applications, showing critical sizes and dimensions for installation and integration with other work.
1.4 DELIVERY, STORAGE AND HANDLING
- Inspect planter liners after delivery for signs of damage during transit.
- Protect planter liners from damage during storage and handling.
- Store planter liners indoors, in their original packaging. Do not stand or walk on planter liners.
1.5 PROJECT CONDITIONS
- Contractor to provide adequate structural support for planter liner units.
- Protect units from damage by adjacent work.
2.0 PRODUCTS
2.1 ACCEPTABLE PRODUCTS/MANUFACTURERS
- Fiberglass Planter Liners, manufactured by Planter Technology, Inc.
1260 San Luis Obispo., Hayward, CA 94544 Tel: (800) 542-2282 FAX (510)
471-6243
2.2 FIBERGLASS PLANTER LINERS
- Materials - All parts shall be constructed of glass fiber reinforced polyester resin.
- Glass fibers shall be Owens Corning or equivalent, 3/4" to 1/2" long.
- Polyester resin shall be compounded by a reputable manufacturer.
- Glass matting shall be Owens Corning or equal with a chrome finish,
minimum two layers of 2 oz. matting per wall section.
- Gel coating shall be Revchem of specified color.
- Construction
Architectural parts shall be fabricated by the hand layup or spray laminate
method using suitable molds to attain the desired surface finish. The
finished reinforced plastic material shall be not less than 5/32"
thick and thicker in those areas requiring additional structural strength.
Where ribs or stiffeners are to be fastened to liner sections by spray laminating over premolded forms, the stiffeners or ribs shall be located and spray laminated into position before the section to which they are to be attached has passed the gel state of curing, and the finished joint shall be strong and durable.
- Performance characteristics and capacities, finished product to yield the following minimum performances:
Flexural strength, psi 23,000
Flexural strength X10 1.1
Tensile strength, psi 23,000
Tensile modulus, X10, psi 1.1
Compressive strength, psi 23,000
Glass content, average 35%
Barcol hardness 50-55
- Finish: Smooth semi-gloss; factory finished.
- Sizes: Modular units fabricated to size by manufacturer as required to fill specified areas. Custom fabricated sizes if necessary.
- Fire retardant requirement can be met with the addition of retardant chemicals to the resin. Additional information is available for this specification.
2.3 PLANTER LINER ACCESSORIES
- Field installed drainage/irrigation connection fitting. Thread-by-thread
thermoplastic drainage adapter, 1/2" to 2"NPT female thread
available. Contractor to locate drainage hole, drill as necessary, and
install fitting.
3.0 EXECUTION
3.1 PREPARATION
- Prior to planter liner fabrication, the contractor shall verify as-built dimensions of planter receptacles ensure proper size, fit and quantity required. 1
- Unless liners have drainage fittings as in 2.3.A, drainage holes to be located and made by contractor in the field to fit to drainage system.
3.2 INSTALLATION
- Install planter liners to allow for easy removal if necessary.
- Provide continuous basal support.
- Install liners level to permit adequate drainage and irrigation.
- Field verification of actual planter receptacle size is frequently overlooked by the contractor, and can lead to delays and additional cost if neglected.